Check valves witout/with pilot control
Description
These hydraulic check valves are part of the spring loaded shut-off valves. The check valves serve for blocking the supply line
in the application of leak-free hydraulic cylinders in combination with low leaking directional valves. The flow B→A is permanently open. In the opposite direction A→B the flow is locked. It can be unlocked by pressurizing the control port Z. The minimum pressure for that depends on the pressure load at port A.
-
space-saving installation options
-
installation without piping
-
pilot control prevents from decompression shocks
-
allows pressure maintenance at uncoupled machine parts
Important information:
Faults can occur in the pressure ratio if the pressure load is too low to unlock the valve. This can effect dangerous malfunctions when decompressing swing clamp cylinders and pull cylinders. Such clamping cylinders must be operated with check valves equipped with pilot control. These valve types are designed for a much lower control pressure. To relieve the piston chamber, a drain connection is required. This must be protected from ingress of dirt and liquids.
Data sheet 700-11
Design:
spring loaded shut-off valves
Operating pressure:
pmax. 500 bar (ports A, B, Z), depressurized (port L)
Volume flow:
Qmax. 20 l/min resp. 30 l/min
Control volume:
0,2 cm³ resp. 0,5 cm³
Unlock ratio:
1:2,9 resp. 1:4,3
Medium:
hydraulic oil acc. to DIN 51524 Tl.1 up to 3; ISO VG 10 up to 68 acc. to DIN 51519
Data sheet (PDF):
Circuit symbols:
without pilot control
with pilot control